Dynamometric 1Ph And 3Ph Power And Power Factor Meter
| DESCRIPTION | ||
|
Dynamometric instruments are used for measurement of active, reactive & absolute power in 1 Phase & 3 Phase systems for balanced / unbalanced load conditions. Watt, Var & VA instruments incorporate current coils, connected in series with the load & pressure coils connected across the load. These instruments work on "Air cored Electro-Dynamometric" principle. |
| FEATURES | ||
| • | SCALE | Linear, Side zero or Center zero are available. |
| • | HOUSING | Sheet Metal (Black painted). |
| • | TERMINAL PROTECTION | Shrouded terminals to protect from accident, (on request). |
| • | GLASS | Anti - glare (on request) |
| ELECTRICAL SPECIFICATIONS | ||
| • | TYPE | Dynamometric. |
| • | OPERATING VOLTAGE | 75V to 500V for 1 Ph. 110V / 440V - PT secondary for 3Ph. |
| BURDEN | <1.25VA upto 75V, <2.5VA - 100V to 150V, < 5VA - 200V to 300V, <10 VA - 350V to 600V |
|
| • | OPERATING CURRENT | 0.5A to 10A for 1 Ph. 1A/5A-CT secondary for 3Ph |
| BURDEN | <5VA upto 5A, <10VA upto 10A. | |
| • | FREQUENCY | 45 ~ 65Hz. (400Hz. on request). |
| • | ACCURACY | Class 1.5 for Watt / Var / VA. 2° for PF. |
| • | DIELECTRIC TEST | 2kV RMS for 1 minute. |
| • | OVERLOAD CONTINUOUS | 1.2 times |
| • | OERLOAD SHORT TIME | 2 times VN / 10 times IN for 5 seconds. |
| • | OPERATING TEMP. | -10°C to 55°C |
| • | STORAGE TEMP. | -20°C to 70°C |
| • | HUMIDITY | up to 95% RH |
| • | CONFORMS TO | I.S. 1248 / I.E.C. 60051 (Part 3) for WATT / VAR & (Part 5) for PF. |
| MECHANICAL SPECIFICATIONS | ||||
| SIZE (mm) | DEPTH (mm) | PANEL CUTOUT (mm) | SCALE LENGTH (mm) | WEIGHT (gms.) |
| 96 x 96 1 ph or 3 ph | See table 1 | 92 x 92+0.8 | 80 (approx.) | See table 2 |
| 144 x 144 1ph or 3 ph | 138 x 138+1.0 | 140 (approx.) | ||
| Table no. 1 (For Depth in mm) | ||||||||||||||||
| Parameter | WATT METER | VAR METER | VA METER | PF METER | ||||||||||||
| 1PH | 3P1E | 3P2E | 3P3E | 1PH | 3P1E | 3P2E | 3P3E | 1PH | 3P1E | 3P2E | 3P3E | 1PH | 3P1E | 3P2E | 3P3E | |
| 96 x 96 | 80 | 80 | 100 | 100 | - | - | 100 | - | 80 | - | 100 | - | 80 | 80 | - | - |
| 144 x 144 | 85 | 85 | 125 | 165 | - | - | 125 | 165 | 85 | - | 125 | 165 | 125 | 125 | - | - |
| Table no. 2 (For Weight in approx. kg) | ||||||||||||||||
| Parameter | WATT METER | VAR METER | VA METER | PF METER | ||||||||||||
| 1PH | 3P1E | 3P2E | 3P3E | 1PH | 3P1E | 3P2E | 3P3E | 1PH | 3P1E | 3P2E | 3P3E | 1PH | 3P1E | 3P2E | 3P3E | |
| 96 x 96 | 0.5 | 0.5 | 0.7 | 0.7 | - | - | 0.7 | - | 0.5 | - | 0.8 | - | 0.6 | 0.7 | - | - |
| 144 x 144 | 1.0 | 1.0 | 1.4 | 1.7 | - | - | 1.4 | 1.8 | 1.8 | - | 1.5 | 1.8 | 1.2 | 1.4 | - | - |
| Note : The connection diagram label is affixed on each meter. |
| Ordering information |
| 1) Type 2) Size, 3) Parameter, 4) Phase & Element and Range 5) Operating Voltage & PTR 6) Operating Current & CTR. |