Products & Services

> </div>
<div class=

Aodd Pump

How the pump Works

Left stroke

The air valve directs pressurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm acts as a separation membrane between the compressed air and liquid, balancing the load and removing mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center block of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to the atmosphere through the exhaust port of the pump.
The movement of diaphragm B toward the center block of the pump creates a vacuum within chamber B. Atmospheric pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area).

mid stroke

When the pressurised diaphragm, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurised air to the back side of diaphragm B. The pressurised air forces diaphragm B away from the center block while pulling diaphragm A to the center block.
Diaphragm B is now on its discharge stroke. Diaphragm B forces the inlet valve ball onto its seat due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center block of the pump creates a vacuum within liquid chamber A. Atmospheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber.

right stroke

At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its exhaust stroke. As the pump reaches its original starting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application.

 
Aodd Pump * Centrifugal Chemical Pumps * Centrifugal Pump * Chemical Centrifugal Pumps * Chemical Pump * Chemical Pumps * Dewatering Pumps * Dosing Pumps * Drain Pumps * Heavy Duty Submersible Slurry Pump * Horizontal Chemical Process Pumps * Hose Pump * Magnetic Chemical Pumps * Magnetic Drive Pump Metallic * Magnetic Drive Pump Non Metallic * Magnetic Pumps * Metering Pumps * P. P. Pump * Pp Chemical Pumps * Pvdf Pump * Sealless Canned Motor Pumps * Sealless Magnetic Pumps * Ss Chemical Pumps * Stainless Steel Chemical Pumps * Submersible Pumps Mfgrs. And Dealers * Chemical Pumps (Chemical Sealless Magnetic Pumps) * Corrosion Resistant Polyproylene Pump * Chemical Process Pump * Centrifugal Process Pump * Chemical Pumps (Centrifugal Ss, Pp Pumps) * Investment Cast Pumps * Chemical Pumps (Centrifugal) * Anticorosive Pumps * Pumps (Chemical Centrifugal Pumps) * Ss Pumps * Stainless Steel Centrifugal Pumps * P. V. D. F. Pumps * Vertical Seal Less Pump * P. P. Centrifugal Pumps * Chemical Dosing Pump * Metering Dosing Pumps * Diaphragm Type Metering Pumps * Plunger Type Metering Pumps * S. S. Monoblock Pumps * Borewell Submersible Pump Set * Submersible Pumps * Ss Centrifugal Pumps * Pp Pumps * Leak Free Pumps * Pfa Pumps * Sealed Pumps * Sealless Magnetic Drive Pumps * Liquid Ammonia Pumps * Aodd Pumps * Industrial Hose Pumps * Canned Motor Pumps * Seal Less Pumps