Create Websire FREE
More Products
More Company
 
 
  ELECTRONIC AUTOMATION P.LTD.
Bengaluru
 
 
 
 
Electronic Timers

Din sized enclosure for Track (Din rail) / Screw mounting.
Front terminal protective cover for safety.
LED indication for timing in progress.
A1DA :External (zero volt / potential free) command contact for timing initiation.

Dimensions: 
Over-all: 22.5 X 75 X 102mm (W X H X D).
Applications: 
AMF panels, Automation panels, HT / LT panels, MCC panels, C & R panels, RTCC panels, Transformer panels and many more

 
Send Email

Programmable Fault Annunciator

Sleek, light weight, ABS enclosure
Super bright, Red color SMD, LED for fault indications
Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.
Multiple units terminals can be connected in parallel to achieve more windows
Each window can be programmed for fault inputs as NO or NC and output as alarm or trip
Above program can be locked by removing the short link across specified terminals
Over voltage protection
Basic Models: M2-2 / M2-4 / M2-6 / M2-8
Advanced Models: M2-12 / M2-16 / M2-24
Available in 12, 16 and 24 windows respectively
Available in wide auxiliary voltage range of 85-270V AC/DC.
Advanced Models with additional features: M2-12R / M2-16R / M2-24R
RS485 output signals are available for displaying Fault and healthy status of each window.
Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window.
Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.

Dimensions: 
Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D)
Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H)
Applications: 
Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc.

 
Send Email

Pre Set Counters

Din sized enclosure for panel mounting.
Wide Voltage range
Front / Rear reset facility provided.
Hold / Restart options (selectable) during power failure.
Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etc
Over-voltage protection
CT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value.
Preset Counts can be programmed with the help of thumbwheel switch
H3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set value
Input sensitivity – programmable (1-100Hz)
Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.

Dimensions: 
Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D)
Applications: 
Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many more

 
Send Email

Energy Management System

EMS-18: VAF Meter with True RMS Sensing,
High brightness red LED display
On site programmable CT(pri &sec) ratio
Protection from dust and water as per IP-51 for front facia
Measurement of basic parameters
Program enable /disable facility available
EMS-11: Measurement of current parameters (L-N) *CT primary and secondary programmable.
EMS-12: Measurement of voltage parameters *PT primary and secondary programmable.
EMS-13: Measurement of frequency parameter.
EMS-14: Measurement of Power Factor parameter.
EMS-02: Measurement of basic parameters.(Current (L-N), Voltage (L-N),(L-L), frequency (average) and Power factor (Total) * CT ratio programmable, RS485 Mod-bus RTU protocol available, Sensing : True RMS .
Program can be locked by removing short link connected across specified terminals
Hold/Scroll Facility available .

Dimensions: 
For EMS-11,EMS-12,EMS-13,EMS-14 Overall: 96 x 96 x 97.5mm (W x H x D) * Cutout : 92 x 92mm (W x H)
For EMS-02,EMS-18 Overall: 96 x 96 x 117 mm (W x H x D) * Cutout : 92 x 92mm (W x H)
Applications: 
Sub metering, machines, Panels, power analysis systems etc

 
Send Email

Monitoring And Motor Protection Devices

Front button for resetting in manual mode
External potential free (zero volt /no voltage) terminal contacts for auto mode.
LED indication for relay status
Window displays the type of fault that has occurred during unhealthy condition
Trip delay time and limits for each parameter can be set digitally
All programs can be locked by removing short link across specified terminals
Unwanted parameters can be by-passed as per user's choice.
Relay can be configured to have NO or NC status during healthy condition
Unit will retain fault till accepted in manual mode
PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.
Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
PVMD – Panel / Flush mounting, PVMD-G Din Rail mounting
PVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current)
Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.
User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.
User can set the in-rush time delay.
Terminals to connect all the 3 phase CTs are provided.
CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5.
PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mounting
Din sized enclosure with Auto / manual Switch

Dimensions: 
Overall: PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G,– 76 x 78 x 115mm (W x H x D)
Cut-out: PVMD, PVIMD– 92 x 92mm (W x H)
Applications: 
Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators, etc

 
Send Email

Temperature Controllers

Universal Input (J,K,PT-100) Selectable.
Wide Voltage Range.
ON / OFF or Self-Tuned Function Selectable.
Single / double set point.
Over Voltage Protection
Compensation offset feature available in TX7-Ua User Friendly Programming through increment / decrement button (TX7-ua)
Indication for sensor, funtion and relay status.
Program enable / disable for sensor, function, hystersis, compensation features in TX7-Ua. Dimension 72x72x128.5

Dimensions: 
Overall: H3-TX Models -48 x 48 x 115mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D)
Cut-out: H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H)

 
Send Email

Power Supply Modules

Compact, light weight and SMPS design
Versatile and easy snap-on mounting on Din-rail
Very low ripple and noise
Regulated and adjusted output
Protection against over voltage, short circuit and over load

Dimensions: 
Overall: MS-01 - 45 x 75 x 116mm, MS-02 – 110 x 86 x 71mm , MS-03 - 155 x 88 x 79mm, MS-04 - 172x150x78mm MS-05 – 22.5 x 75 x 97mm (W x H x D)
Applications: 
PLC, DC Panels, DC Solenoids, DC Relay boards, Battery Charging Panels, etc.

 
Send Email

Tacho Meter

Micro-controller based design with world class Indian software.
Non-contact sensing through reflected light beam on reflective sticker.
LCD display
Input sensing indication through LED.
Memory facility to retain measured value.
Portable, lightweight, strong and elegant ABS enclosure.
Accuracy: 1RPM up to 5,000 RPM and 0.05% of the reading above 5,000 RPM.
Resolution: 0.1RPM up to 5,999 RPM and 1RPM at and above 6,000RPM.
Calibration certificate provided along with tachometer - traceable to national and international standards.

Dimensions: 
Over-all: 72 X 170 X 38mm (W X H X D).
Applications: 
Motors, Pumps, Generators, Engines and many more

 
Send Email

Time Switches

Switches On and Off 4 times in a day with respect to real time.
LED indication for relay status, LCD display for real time clock.
User friendly programming with manual over ride facility.
Clock hour and Clock minute buttons can be enabled by shorting terminals to program RTC.
For TS-203, TS-203B : Use (1.5Vx2)AA size Batteries

Dimensions: 
TS-203 :Over-all:72 x 72 x 84mm (W x H x D)
TS-203B : Over-all:110 x 86 x 68mm (L x W x D)
Applications: 
Street lightings,advertising sign boards etc

 
Send Email

Light Switch

This is a light switch working on direct or reflective transmission principle.
It consists of high intensity emitter source and high sensitive receiver
The signal received from the receiver will operate a relay with ON delay or OFF delay depending on mode selected.
The time range can be 0.3 sec / 30 sec.

Dimensions: 
EALS-4505 Dimension:45 x 75 x 116mm(WxHxD) EALSR-01:19.2 x 35.5 x 127.5mm (W x H x D) EALSE-01:19.2 x 35.5 x 127.5mm (W x H x D)
Applications: 
Hopper Feed Control,Stop Motion Device, Light Barriers, Level Control, Intrusion Alarm.

 
Send Email

Solar Charge Controllers

Maximum Power Point Tracking technology increases the efficiency of PV system.
Advanced Interleaved buck topology
Full electronic protection (Reverse Polarity, Over-Voltage and Over-Current).
Multi-stage Battery charging:- Boost/ Absorption/ Trickle Modes.
For Lumina-02 :MPPT protects battery from being discharged below lower cut-off voltage.Automatic Dusk to Dawn Load ON feature.Efficient in charging Lead Acid Batteries.

Dimensions: 
Dimension:149 x 86 x 77mm(WxHxD)
Applications: 
Solar street light, Roof top solar solutions, Solar Home systems

 
Send Email

Acdb Panel

Monitors the parameters of power & energy using Multifunction energy meter.
Change over mechanism to switch the load from solar to grid
Convenient Installaton and Maintenance.
Distribution facility to existing LT panel .

Dimensions: 
Overall: 450 x 350 x 200mm (W x H x D)

 
Send Email

Ajb Box

To obstruct the sudden surges due to lightening strokes during cloudy and rainy conditions and ground the surges immediately.
Purely Customizable based on customer needs.
Reliable electric safety to avoid hazard.
Fuses for overload protection on each string.

Dimensions: 
Over-all : 278 X 278 X 130 mm (W X H X D).
Applications: 
Solar waterpump system, Solar home system etc

 
Send Email

Interface Relay Module

“Sigut” termination for electrical safety.
LED indication for Relay status.
DIN Rail Mounting

Dimensions: 
Dimension:23x74x53mm(WxHxD)

 
Send Email

Photo Relay

Designed for the control of cotton level in laminae duct in ERM cleaners.
Designed for Industrial Environment
High Intensity pulsed Infra Red Emitter
Time Delay up to 20 Seconds.
Highly immune to Ambient Light
45mm Din Rail mounting.

Dimensions: 
Overall:45 x 75 x 116mm (W x H x D)
Applications: 
Designed for control of cotton level in laminae duct in ERM cleaners and similar application.

 
Send Email

 
  CONTACT US AT
ELECTRONIC AUTOMATION P.LTD.
ADDRESS : No.20, K.h.b.industrial Area, Yelahanka
Bengaluru-560064 (Karnataka)


Contact : ,

Send Email


Send Email

WEBSITE : www.goldenpages.in/eaplindia
Contact Person :


Mobile : Send SMS
 
Home | About Us | Products | Contact Us |
 
Copyrights @
Electronic Automation P. Ltd.
Site Designed & Maintained by Aman Infotech
 
 
Back to Top


Acdb Panel, Ajb Box, Counter Electronic, Digital Counter, Digital Counters, Digital Timers, Electronic Timers, Energy Management System, Interface Relay Module, Light Switch, Monitoring And Motor Protection Devices, Photo Relay, Power Supply Modules, Pre Set Counters, Programmable Fault Annunciator, Programmable Timers, Solar Charge Controllers, Tacho Meter, Techo Meters, Temp. Controllers, Temperature Controller, Temperature Controllers, Temperature Scanner, Time Switches, Timers