Create Websire FREE
More Products
More Company
 
 
  ANU VIDYUT
Roorkee
 
 
 
  • Warning Bell For Level Crossing
  • Contact Us
  •  
    Flasher Relay

    Flasher Relay is used in railway signaling installations to give flashes at the rate of 40 to 60 per minute. Potential free contacts are given to bear a load from 3 t01 0 Amps in different models. It is so designed that the failure of any component results in no indication. Encased in a sheet metal box has also an over voltage protection. It is available in different models to work at 12 or 24 or 60V DC or 110V AC.
    Providing you the best range of Railway Signalling Equipment such as Flasher Relay, Fail Safe Electronic Timer, Earth Leakage Detector, Cable Insulation Tester and Delay Timer with effective & timely delivery.
    Under the guidance, direction and motivation of our founder member, we have shown tremendous progress in the field of electronic industry. With state-of-the-art manufacturing unit and highly trained electronic engineers, our products are compact and maintenance free. We also have a team of qualified technocrats who can prepare the designs according to the usage and utility of the products so that they fulfill the customer's requirements.

     
    Send Email

    Fail Safe Electronic Timer

    We manufacture safe electronic timer which replaces the thermal element relay used in signaling circuits. This fully solid state device is relay less and the time base is generated through a quartz crystal to give a high repeat accuracy. It is meant to control railway signaling circuits where a fixed time delay of 60 or 120 seconds is required. It works on 24V DC power supply.

     
    Send Email

    Earth Leakage Detector

    We offer Earth Leakage Detector which is commonly known as ELD, this equipment continuously monitors the insulation of a cable with respect to the Earth. It is widely used in railways to monitor signaling cables on AC and DC circuits. The leakage value can be pre-set by the user in the range of 2K Ohm to 1 Meg ohm. Available in multiple of 4 Channels i.e. 4/8/12 Channels. The single/ multi channel equipment has twin indicating arrangements of an audio alarm plus a panel meter. It also includes a built-in Cable Insulation Tester.

     
    Send Email

    Cable Insulation Tester

    Cable Insulation Tester is similar to ELD with the most important difference that this monitors the signaling cables in un-energized mode. Insulation Resistance value ranging from 500 KO to 100 MO. It has a special feature, in case a pair is energized the instrument automatically stops functioning.

     
    Send Email

    Delay Timer

    Our delay timer is available from 1 sec to 60 minutes timings in 10 steps with a choice of ON/OFF delay. The timer is suitable for continuous working in railway signaling and indoor use. Two change-over un-energized contacts with 5 Amps rating are provided on DIN rail 35mm enclosure.

     
    Send Email

    Transmission Measuring Set

    We manufacture transmission measuring set which is designed to fulfill all type of requirements for determination of signal level, insertion loss, transmission loss and return loss in cable circuits used in audio telephones. With a measuring range from + 10 to -50 dB it is battery operated with a built in charger which is ideal for the field use. It is suitable for 600 and 1120 impedance.

     
    Send Email

    Cross Talk Measuring Set

    Our cross talk measuring set is a portable instrument which is capable of measuring cross talk in the audio frequency range with a built-in AF generator and measuring detector. As the measuring range starts from zero dB it can be conveniently used as a transmission measuring set. With a measuring range from +10 to -80 dB is is suitable for 470/600/1120 U impedance.

     
    Send Email

    Control Office Equipment

    Also called as train traffic control equipment, our control office equipment works on DTMF voice frequency signaling and has applications in omnibus speech circuits like section control, TPC control, Deputy Control etc., used in railways. This equipment mainly consists of a code generator and two way voice communication, which can run in two-wire as well as four- wire control circuits in conjunction with the way station equipment.
     

     
    Send Email

    Way Station Equipment

    We manufacture Way Station Equipment(2W/4W) which is separately available for two- wire and four-wire operation. It consists of voice communication circuit, code reception and recognition circuit with ringing and ring-back transmission facility.

     
    Send Email

    Control Telephone

    We manufacture Control Telephone(2W/4W) which is used with their respective way station equipment. This telephone facilitates communication between the controller and the way station working on two/four-wire.

     
    Send Email

    Two Wire Ten Way Telephone

    This system is used for point to point communication between Station Master & Cabin ASM of a yard/ Level Crossing gate, Cabin ASM & Station Master/Level Crossing gate, Level Crossing gate & Cabin ASM/Station Master, Level Crossing gate & Level crossing gate, cabin ASM & cabin ASM etc. where the number of points to be connected are 2 to 11. It shall also be used as an intercom wherever 2 to 11 parties will be required to be connected for communication on 2 wire line.

     
    Send Email

    Electronic Magneto Telephone

    Our electronic magneto telephone is designed to meet communication requirement in railways and similar set-ups in between two or more stations. It is fully solid state and works on 3Volts through built-in case for 2X D3 cells or alternately connected through 3Volts battery. It operates within a radius of 65 km and is designed to replace magneto telephone with a hand-cranking generator.

     
    Send Email

    Phase Angle Meter

    Phase Angle Meter is a compact direct reading instrument suitable for reading phase angle between voltage-voltage, voltage-current and current-current. In voltage range of 60 of 440 and current range of 1 to 5 Amps. Available in digital and analog read-out it operates on 230V/50Hz

     
    Send Email

    Line Frequency Meter

    Line frequency meters are specially designed to measure line frequency at power plants, sub-stations, distribution centers etc. Cased in various is 180 to 280V on single phase AC and sensing voltage from 50 to 300V. They can be set to trip as per user requirement.

     
    Send Email

    Time Interval Meter

    Time interval meters are used for the measurement of time interval from 0.1 milli-sec. to 9999 secs.(2 hrs 45 mins.). This is ideally suited for measuring switching time of Relays, trip time & on time of circuit breakers, fusing time of fuse elements, travel time of switches and contactors etc. Type 1425 series can also be used as an accurate stopwatch.

     
    Send Email

    Db Meter

    DB Meter meets all type of requirements for determination of signal level, transmission loss in V.F. transmission line. The instrument is provided with a rechargeable battery and a charger and is housed in a sturdy metal case ideal for field use.

     
    Send Email

     
      CONTACT US AT
    ANU VIDYUT
    ADDRESS : C-1, Indl Estate, Roorkee,
    Roorkee Dist. : Haridwar-247667 (Uttarakhand)


    Contact : ,

    Send Email


    Send Email

    WEBSITE : www.goldenpages.in/anuvidyut
    Contact Person :


    Mobile : Send SMS
     
    Home | About Us | Products | Contact Us |
     
    Copyrights @
    Anu Vidyut
    Site Designed & Maintained by Aman Infotech
     
     
    Back to Top


    Cable Insulation Tester, Control Office Equipment, Control Telephone, Cross Talk Measuring Set, Db Meter, Delay Timer, Digital Thermometers, Earth Leakage Detector, Electronic Magneto Telephone, Fail Safe Electronic Timer, Flasher Relay, Line Frequency Meter, Phase Angle Meter, Products, Time Interval Meter, Transmission Measuring Set, Two Wire Ten Way Telephone, Way Station Equipment